English  
   
   
Home > Á¦Ç°¼Ò°³ > ¶óÀÎÀÎÅÍ·¢Æ¼ºê UPS > Smart King XL Series

SMK ( XL) Series 1000/2000/3000
 

³»ÀåÇü ¹èÅ͸® / ÀϹÝÀû Á¤Àüº¸»ó½Ã°£º¸´Ù ¿À·£ ¹é¾÷ÀÌ ÇÊ¿äÇÑ ºÎÇÏÀåºñ¿¡ ÀûÇÕÇÑ UPS .

±â´É :

  • ¼ø¼öÁ¤ÇöÆÄ Ãâ·Â
  • ¿ÜÀåÇü ¹èÅ͸® ÆÑ¿¡ ÀÇÇÑ Á¤Àüº¸»ó½Ã°£ ¿¬Àå°¡´É
  • ÃæÀüº¸µå³»Àå (Á¤»ó : 5.5A, 3.5A~8A Á¶Àý °¡´É)
  • ¶óÀÎÀÎÅÍ·¢Æ¼ºê µðÀÚÀÎ
  • ºÎ½ºÆ®(½Â¾Ð) ¹× ¹÷(°¨¾Ð) AVR
  • Hot swappable ¹èÅ͸® ±³Ã¼
  • ¿ÏÀü µðÁöÅÐ ¸¶Ÿå·Î ÇÁ·Î¼¼¼­ °ü¸®
  • ½º¸¶Æ® RS-232 Åë½Å Æ÷Æ®
  • ¹ø°³ ¹× ¼­Áö º¸È£
  • ´Ü¶ô ¹× °úºÎÇÏ º¸È£
  • 50/60Hz Á֯ļö ÀÚµ¿ °¨Áö
  • Tel/modem ÀÎÅÍ³Ý ½ºÆÄÀÌÅ© º¸È£
  • ¼ÒÇÁÆ®¿þ¾î¿¡ ÀÇÇÑ ½º¸¶Æ® Àü¿ø °ü¸®
  • Äݵ彺ŸƮ (DC power on)
  • °úºÎÇÏ, ¿Â¶óÀÎ, ¹èÅ͸® »óÅ LED¶Ç´Â LCD µð½ºÇ÷¹ÀÌ
  • ºÎÇÏ/¹èÅ͸® Àü¿ø¹ÌÅÍ µð½ºÇ÷¹ÀÌ
  • Áøº¸µÈ ¹èÅ͸® °ü¸® (ABM)
  • ¿¡³ÊÁö Àý¾à (UPS ½½¸³¸ðµå)
  • »çÀÌÆ® ¿ÍÀ̾ ÆúÆ® °æ°í *
  • SNMP °¡´É

    * ±â´ÉÀº ´ÜÁö 100V/110V/115V ¸ðµ¨¸¸ °¡´É


¿À·£ Á¤Àüº¸»ó½Ã°£ ¿äû¿ë ¸ðµ¨    (¹èÅ͸® ºÒÆ÷ÇÔ) SMK(AL)-1000A SMK(AL)-2000A SMK(AL)-3000A
ÀÔ·Â ¿ë·® 1000VA 2000VA 3000VA
Àü¾Ð +/-25% ¶óÀÎÀÔ·Â, ´Ü»ó
Á֯ļö 50 or 60Hz +/-5Hz (ÀÚµ¿°¨Áö)
Ãâ·Â Àü¾Ð
(on battery)
¼ø¼öÁ¤ÇöÆÄ  -  Á¤»óÀÇ +/-5% , Á¤»óÀÇ +/-10% (¹èÅ͸® Àú ÃæÀü °æº¸ÈÄ)
Á֯ļö
(on battery)
50 or 60Hz +/-0.5%
ÀÚµ¿Àü¾ÐÁ¶Àý(AVR)

AVR [¸¸¾à Á¤»óÀü¾ÐÀÇ -9%~-25%ÀÇ Àü¾ÐÀÌ µÉ °æ¿ì , 15% ÀÚµ¿Àü¾Ð »ó½ÂµÇ¸ç, Á¤»óÀü¾ÐÀÇ +9%~ +25%ÀÇ Àü¾ÐÀÌ µÉ °æ¿ì , 15% ÀÚµ¿Àü¾Ð Ç϶ôÀ» ½ÃÅ´]

º¸È£ ¹× ÇÊÅ͸µ ½ºÆÄÀÌÅ©º¸È£ 320 Joules, 2ms
ÀÔ·Â Ç»Áî: Àü ¸ðµ¨.     ºê·¹ÀÌÄ¿: ¸ðµ¨ 2000A/3000A
EMI/RFI ÇÊÅÍ 10dB at 0.15MHz, 50 dB at 30MHz
°úºÎÇÏ º¸È£ ºÎÇϰ¡ Á¤»óÀü¾Ðº¸´Ù 110% ÃʰúÇÏ¿© 20ÃÊ ÀÌ»ó, 125%¿¡¼­ 5ÃÊÀÌ»ó °æ°úµÉ °æ¿ì UPS´Â ÀÚµ¿ ¼Ë´Ù¿î
Àýü½Ã°£ 2/4 milliseconds , °¨Áö½Ã°£ Æ÷ÇÔ
´Ü¶ô UPS Ãâ·Â Áß´Ü ¶Ç´Â ÀÔ·ÂÇ»Áî(ºê·¹ÀÌÄ¿) º¸È£
¹èÅ͸® ŸÀÔ Hot swappable, ¹«º¸¼ö ¹ÐÆóÇü
ÃæÀü½Ã°£ 4 ½Ã°£ (¿ÏÃæÀüÀÇ 90%±îÁö )
º¸È£ ÀÚµ¿ ÀÚ°¡Áø´Ü ¹æÀü º¸È£, ¹èÅ͸® ±³Ã¼ Ç¥½Ãµî
Á¤Àüº¸»ó½Ã°£
(one PC and one 15" monitor)
¡Ü 90 min ¡Ü 120 min ¡Ü 140 min
¼øÁß·® Kg
(lbs)
Ÿ¿ö 25.0 (55.0 lb) 30.0 (66.0 lb) 30.0 (66.0 lb)
19" ·¢¸¶ÀºÆ® 26.1 (57.4 lb) 28.4 (62.5 lb) 28.4 (62.5 lb)
±Ô°Ý
W x D x H (mm)
Ÿ¿ör 170 x 450 x 226 (6.7" x 17.7" x 8.9")
19" ·¢¸¶¿îÆ® 483 x 381 x 130 (19.0" x 15.0" x 5.1")
LCD Ç¥½Ãµî »óÅ ¶óÀÎ, ¹ÙÀÌÆÐ½º, INV, ¹é¾÷, ÆúÆ®, ¹èÅ͸® ¿ë·®, ºÎÇϿ뷮, ÀÔ·ÂÁ֯ļö, Ãâ·ÂÀü¾Ð, Ãâ·ÂÁ֯ļö, ¿Âµµ, ÆúÆ®»óÅÂ, ºÎÇÏ Ç¥½Ã
ÀÎÅÍÆäÀ̽º RS232 º£Å͸® ÀúÃæÀü, ¿¹¾à UPS on/off, AC ÀÔ/Ãú·Â Àü¿ø »óÅ ǥ½Ã
µå¶óÀÌ ÄÁÅÃÆ® Á¤Àü, ¹èÅ͸® ÀúÃæÀü ½ÅÈ£ ¹× ÄÄÇ»ÅͷκÎÅÍ ¼Ë´Ù¿î ½ÅÈ£¸¦ ¹ÞÀ»¶§
¿É¼Ç Novell, SNMP, Windows NT, Windows 95/98/2000/ME
°æº¸À½ ¹èÅ͸® ¹é¾÷ ´À¸°°æº¸À½ (¾à 0.25Hz)
¹èÅ͸® ÀúÃæÀü ºü¸¥ °æº¸À½ (¾à 1.00Hz)
°úºÎÇÏ °è¼ÓÀûÀÎ °æº¸À½
ȯ°æ ÀÛµ¿ ÃÖ´ëÇ¥°í 3,500 ¹ÌÅÍ, ½Àµµ 0-95%, ¿Âµµ0-40 µµ½Ã
¼ÒÀ½ <45dBA ( Ç¥¸éÀ¸·ÎºÎÅÍ 1 ¹ÌÅÍ)
ÀúÀåÁ¶°Ç ÃÖ´ëÇ¥°í 15,000 ¹ÌÅÍ
Ÿ¿ö¸ðµ¨ SXL-1000A SXL-1500A SXL-2000A SXL-3000A
19" ·¢¸¶¿îÆ® SXL-1000A-RM (3U) SXL-1500A-RM (3U) SXL-2000A-RM (3U) SXL-3000A-RM (4U)
ÀÔ·Â ¿ë·® 1000VA 1500VA 2000VA 3000VA
Àü¾Ð +/-25% at line input, single phase
Á֯ļö 50 or 60Hz +/-5Hz (auto sensing)
OUTPUT Àü¾Ð
(on battery)
Pure sine wave at +/-5% of nominal, -10% of nominal after low battery warning
Á֯ļö
(on battery)
50 or 60Hz +/-0.5%
ÀÚµ¿Àü¾ÐÁ¶Àý(AVR) AVR automatically increase output voltage 15% above input voltage if -9% to -25% of nominal.
AVR decrease output voltage 15% below input voltage if +9% to +25% of nominal
PROTECTION
& FILTERING
Spike Protection 320 Joules, 2ms
Unit Input Fuse for 110V models except 3000A, breaker for 3000A and 220V models
EMI/RFI filter 10dB at 0.15MHz, 50 dB at 30MHz
Overload Protection UPS automatic shutdown if overload exceeds 110% of nominal at 20 seconds and 125% at 5 seconds.
Transfer Time 2/4 milliseconds (typical), including detection time
Short Circuit UPS output cut off immediately or input fuse(or breaker) protection
BATTERY Type Hot swappable, sealed, maintenance-free lead acid
Typical Recharge Time 4 hours (to 90% of full capacity)
Protection Automatic self-test & discharge protection, Replace battery indicator
Battery Quantity 4 pcs 3 pcs 4 pcs 4 pcs
Built in fast charger Nominal : 5.5A, 3.5A~8A adjustable
Back Up Time Tower Model Full Load 7 ~ 8 minutes 13 ~ 14 minutes 13 ~ 14 minutes 8.5 ~ 9.5 minutes
Half Load 28 ~ 29 minutes 33 ~ 34 minutes 33 ~ 34 minutes 21 ~ 22 minutes
19" RM Model Full Load 7 ~ 8 minutes 7 ~ 8 minutes 6 ~ 7 minutes 5 ~ 6 minutes
Half Load 28 ~ 29 minutes 17 ~ 18 minutes 17 ~ 18 minutes 17 ~ 18 minutes
Net Weight Kg
(lbs)
Tower Model 22.5 (49.5 lb) 46 (101.2 lb) 50 (110 lb) 57 (125.4 lb)
19" Rack-mount 18.8 (41.4 lb) 23.5 (51.7 lb) 26.4 (58.1 lb) 46.5 (102.3 lb)
DIMENSION
W x D x H (mm)
Tower 170x450x215
(6.7"x17.7"x8.5")
170 x 480 x 430
(6.7" x 18.9" x 16.9")
170x580x430
(6.7"x22.8"x16.9")
19" Rack-mount 483 x 560 x 130 (19.0" x 22.0" x 5.1") 483x560x178
(19.0"x22.0"x7.0")
INTERFACE RS232 Detect battery low, Schedule UPS on/off, AC input/output power status display.
Dry contact Sends AC fail and battery low signals, and receives shutdown signal from computer.
Option Novell, SNMP, Windows NT, Windows 95/98/2000/ME
ALARM Battery Back-up Slow beeping sound (about 0.25Hz)
Battery Low Rapid beeping sound (about 1.00Hz)
Overload Continuously beeping sound
ENVIRONMENT Ambient Operation 3,500 meters max, elevation. 0-95% humidity non-condensing, 0-40 deg
Audible Noise < 40 dBA
(1 m from surface)
< 45 dBA
(1 meter from surface)
Storage Condition 15,000 meter max. elevation