| VGD 60K33/80K33 | |
|
Intelligent, digitalized, and true galvanic isolation online design specially designed for Power Plants. Features :
|
| MODEL NAME | VGD-60K33 | VGD-80K33 | |
| CAPACITY | 60KVA/48KW | 80KVA/64KW | |
| P.F. | 0.8 (on-line, double conversion, multiprocessor control) | ||
| INPUT | Voltage | 220V / 380V, 230V / 400V, 240V / 415V (3 Phase 4 Wire) | |
| Input range | +/- 15% | ||
| Frequency | 50Hz / 60Hz +/- 5% | ||
| Rectifier-Charger | With soft start | ||
| PFC | PF > 0.97 | ||
| OUTPUT | Voltage | 220V / 380V, 230V / 400V, 240V / 415V (3 Phase 4 Wire) | |
| Accuracy | +/- 1% at steady
state. +/- 2% at dynamic state (load fluctuations 100% ~ 0% ~ 100%) |
||
| Frequency | 50Hz / 60Hz synchronized +/- 4% , free running +/- 0.05% | ||
| Slew Rate | +/- 1Hz/s | ||
| Waveform | Sine-wave | ||
| Efficiency | 90% to 92% | ||
| Total Harmonic Distortion | < 3% | ||
| Phase displacement | 120° +/-1% (balanced load) , 120° +/-% (imbalances 50% of the load) | ||
| Dynamic recovery time | 10 ms, at 98% of the state value | ||
| Admissible overload | 125% (10'), 150% (1') | ||
| Amissible crest factor | 3:1 | ||
| Imbalance output voltage with load 100% unbalanced | <2% | ||
| Static Bypass | Type and activation | Solid state | |
| Voltage | 220V / 380V, 230V / 400V, 240V / 415V (3 Phase 4 Wire) | ||
| Frequency | 50 or 60Hz | ||
| Activation criterion | Microprocessor control | ||
| Transfer Time | Nil | ||
| Admissible overload | 400% for 10s, Short circuit for 40ms | ||
| Passage to Bypass | Immediate, for overloads for over 160% | ||
| Manual Bypass | Type | Without interruption | |
| Voltage | 220V / 380V, 230V / 400V, 240V / 415V (3 Phase 4 Wire) | ||
| Frequency | 50 or 60Hz | ||
| Batteries | With batteries | YES | |
| Battery test | YES, programmable | ||
| Communication | RS-232/485 ports as standard and AS-400 | ||
| Charger | Technology | PWM | |
| Charging current | 0.2C | ||
| Float voltage | 13.6V | ||
| Recharging time | From the end of back-up time to 80% of the total charge 3 to 4 hours depending on the power of the device (depending on type of batteries) | ||
| Environment | Noise Level | <60 dBA (at 1m. distance and 100% load) | |
| Operating temperature | From 0° to 40°C | ||
| Protection UNE 2032478IR | IP20 | ||
| Electromagnetic compatibility | En50091-2 | ||
| Safty | EN-50091-1, EN-60950 | ||
| Marking | CE | ||
| Quality | ISO-9001 | ||
| Connection | By input / output terminals | ||
| Dielectric rigidity | 2,500V AC for 1 min. | ||
| Ventilation | Forced | ||
| Humidity | Up to 95% without condension | ||
| Maximum working height | 2,400 M s.n.m | ||
| Dimension DxWxH | 755 x 600 x 1255 mm | ||
| Weight (kg) | 770 | TBA | |