| Ultimate 4K/5K/6K/8K LCD | |
| The Ultimate On-Line Power Protection. Features :
|
|
| Tower Model (LCD display) | ULT-4000-LCD | ULT-5000-LCD | ULT-6000-LCD | ULT-8000-LCD | ||
| Power Rating | P.F.=0.7 | 4000VA | 5000VA | 6000VA | 8000VA | |
| AC INPUT | Voltage | 85~138V or 170~276V | ||||
| Frequency | 50Hz or 60Hz +/- 3Hz | |||||
| Phase | Single phase | |||||
| Power Factor | >=0.98 | |||||
| Battery | DC Voltage | 144V | 240V | |||
| Back-Up Time | Full Load | 6 mins | 9 mins | 7 mins | 8 mins | |
| Half Load | 15 mins | 25 mins | 20 mins | 22 mins | ||
| Type | Sealed lead acid battery, maintenance free | |||||
| Protection | Battery low cut-off without draining any current | |||||
| Recharge Time | About 8 hours to 90% after fully discharged | |||||
| AC OUTPUT | Frequency | 50Hz / 60Hz (Auto detection) | ||||
| Voltage | 100/200V or 110/220V or 115/230V or 120/240V (1 ~ 3W selectable) | |||||
| Voltage regulation | +/- 2% | |||||
| Frequency Stability | +/- 0.5% | |||||
| Power Factor | 0.7 (lagging) | |||||
| Harmonic distortion | < 3% of T.H.D. at linear load | |||||
| Overload Detection | 105% for 10 seconds and 130% +/-10% for 300 ms (Crest factor ratio 3:1) | |||||
| EFFICIENCY | AC to AC | > 85% | ||||
| TRANSFER | Power failure or Recovery | 0 ms | ||||
| Overload disappear | Auto transfer to UPS | |||||
| UPS to Bypass or vice versa | 0 ms | |||||
| NOISE LEVEL | 1m. distance19" Rack-mount | < 55 dBA | ||||
| LED | Status | Line input (green), inverter output (green), bypass (yellow), fault (red) | ||||
| LCD | Status | Indicate line, bypass, inverter backup, fault, bat capacity, load capacity, I/P voltage, I/P frequency, O/P voltage, O/P frequency, internal temperature, fault status. | ||||
| ALARM | Battery discharge | The first warning will beep every 4 seconds to indicate battery in use. The second warning will beep every 1 second to signal battery low. | ||||
| UPS Fault | Continuous beeping sound | |||||
| ENVIRONMENT | Temperature | 0 degree ~ 40 degree | ||||
| Humidity | 0% ~ 95% (Non condensing) | |||||
| Interface | Dry contact | Sends AC failure and battery low signals, and receives shutdown signal from computer. | ||||
| RS232 | Detect power failure, Battery low, Schedule UPS on/off, AC power status display | |||||
| Option | Novell, SNMP, Windows NT | |||||
| Physical size W x D x H mm (inch) |
Tower model | 260 x 555 x 700 (10.2" x 21.9" x 27.6") | 340 x 660 x 710 (13.3"x25.9"x28.0") |
|||
| Net Weight Kgs (lbs) |
Tower model | 94 (207 lbs) | 114 (250lbs) | 114 (250 lbs) | 200 (440lbs) | |